!"# $%& '()*(+%,-. /#--) 0"+.1%# --- บร ษ ท เอ นไซ กร ป จ าก ด ---
|
|
- Patricia Wells
- 5 years ago
- Views:
Transcription
1 !"# $%& '()*(+%,-. /#--) 0"+.1%#
2 w บรษ w ท w.e เอ น ns ไซ ci กร gr ป ou จ า p. ก ด co -m - ---
3 w บรษ w ท w.e เอ น ns ไซ ci กร gr ป ou จ า p. ก ด co -m - ---
4
5
6 Product Specification *Weights and Dimensions *Normative Reference *Technical Data DAIWA
7 Trade Size Designator Weights and Dimensions Electrical Metallic Tubing (EMT) Electrical Metallic Tubing (EMT), also commonly called thin-wall, is a listed steel raceway of circular cross section which is unthreadewd, and nominally 10 feet long. Twenty foot lengths are also available. Covered by Article 358 of the NEC,ANSI C80.3, UL 797 Nominal Outside Diameter Reference Inside Diameter DAIWA Reference Wall Thickness Length Minimum Weight per 10 Unit Lengths U.S. Metric mm mm mm mm kg 1/ / / / NOTE - Applicable tolerances Length : +/- 6 mm. Outside Diameter: for trade size 1/2 through 2 : +/ mm. Trade Size Designator Intermediate Metal Conduit (IMC) IMC has a reduced wall thickness, when compared to RSC, and weighs about one-third less than RSC. The outside has a galvanized coating for corrosion protection and the inside has an approved organic corrosion-resistant coating. Covered under Article 342 in the NEC, UL 1242 Nominal Outside Diameter Reference Wall Thickness Length without Coupling Minimum Weight per 10 Unit Lengths with Couplings Attached U.S. Metric mm mm mm kg 1/ / / / / / NOTE - Applicable tolerances Length : + 6 mm. Outside Diameter: for trade size 1/2 through 2 : +/- 0.2 mm. for trade size 2-1/2 through 4 : +/- 0.3 mm. Wall Thickness: for trade size 1/2 through 1 : mm. for trade size 1-1/4 through 4 : mm.
8 Trade Size Designator Trade Size Designator Number of Threads per 25.4 Rigid Steel Conduit (RSC) Rigid steel conduit is the heaviest-weight and thickest wall conduit. Where galvanized by the hot-dip process, it has a coating of zinc on both the inside and outside. The installation of Rigid Steel Conduit (RSC) is covered by Article 344 of the National Electrical Code (NEC ), ANSI C80.1, UL 6 Nominal Outside Diameter Dimensions of Threads L4 Total Length of Threads Reference Wall Thickness L2 Effective Length of Threads DAIWA E0 Pitch DIameternat End of Conduit Length without Coupling U.S. Metric mm mm mm kg 1/ / / / / / NOTE - Applicable tolerances Thread Length : +/- 1 thread, recommended practice +0, -1 Pitch +/- 1 turn is the maximum variation permitted from the gaging face of the working thread gauges. Minimum Weight per 10 Unit Lengths with Couplings Attached U.S. Metric mm mm mm kg 1/ / / / / / NOTE - Applicable tolerances Length : +/- 6 mm. Outside Diameter: for trade size 1/2 through 2 : +/- 0.4 mm. for trade size 2-1/2 through 4 : +/- 0.6 mm. for trade size 5 through 6 : +/- 1.5 mm. Wall Thickness: -12.5%
9 Dimensions of 90 degree Elbows Dimensions of Coupling Trade Size Minimum Radius to Maximum Straight Designator Center of Tubing Length Ls Each End U.S. Metric mm. mm. 1/ / / / / / Trade Size Outside Pitch Chamfer Designator Diameter Diameter Diameter U.S. Metric mm. mm. mm. 1/ / / / / / Note - Applicable tolerance Outside Diameter tolerance : plus tolerances : no requirement minus tolerances - for tradesize smaller than 1-1/4 " mm. for trade size 1-1/4 " and larger :1%
10 Normative Reference (Engineering Specification) 1. Scope This specification relates to the Steel Conduit Accosiations. 2. Engineering Standard DAIWA Industry Company Limited manufactures the products by following the standard of ANSI, UL (International Standard) with a high technology machine. Therefore, DAIWA s conduit is satisfied by the high quality products. Design Codes of Practice: ANSI / ASME B ANSI / IEEE ANSI / NFPA ANSI C ANSI C Tubing ANSI C UL 6 UL 797 UL 1242 ANSI / NEMA FB NEMA FB IEC IEC General Purpose Pipe Threads Metric Practice National Electrical Code Specification for Zinc Coated Rigid Steel Conduit Specification for Zinc Coated Electrical Metallic Intermediate Metal Conduit (IMC) Zinc Coated Rigid Metal Steel Electrical Metallic Tubing Intermediate Metal Conduit Fitting, Cast Metal Boxes, and Conduit Bodies for Conduit, Electrical Metallic Tubing, and Cable Selection and Installation Guidelines for Fittings for use with conduit. Extra heavy duty electrical rigid steel conduit Fittings for extra-heavy duty electrical rigid steel conduit DAIWA
11 Technical Data The product of DAIWA white conduit is satisfied the requirements of NEMA & UL: 1. General (raw material) DAIWA is made from ERW steel pipe. The highest technology pipe forming in the world. Threrfore, DAIWA white conduit have the properties of circular cross section, thereby facilitating the cutting of clean, true threads. All seams are thoroughly welded. 2.Welding : A slight bead on interior wall is conform with UL standard: A welded seam shall be without any metal trimming, sharp edge, or sharp and the bead does not decrease the interior diameter of the tube by more than inch (0.38 mm) for trade sizes ½ - 2(16-53) or 0.20 inch(0.51 mm) in height for the trade size 2 1/2-4(63-103) ERW = The Electrical Resistance Welding Production DAIWA
12 3. Protective coating (Anti-corrosion) DAIWA s conduit is made from SABIN CORR 330 anti-corrosion which forms a barrier film to protect ferrous and non-ferrous metals from moisture, salty atmosphere, corrosive fumes. 4. Threading & Chamfering DAIWA s conduit is the perfect tapered thread for its entire length,and conform to ANSI/ASME B Therefore DAIWA s conduit is gualified to give satisfaction as followed 1. Easy to installation 2. Compatible with the common conduit fitting follow ANSI / NEMA FB , NEMA FB DAIWA
13 5. Bending properties DAIWA s conduit is capable of being bent cold into a quarter of a circular around a mandrel, the radius of which conform to requirements ANSI and UL, without developing cracks at any portion and without opening the weld. DAIWA
14 DAIWA s Research & Developement * 3C Product (New Innovative for steel conduit) DAIWA
15 Technology 3 C Anti Corrosion by Corodex BF Enamel Coating by RAMA Elecro-Zinc Platting Cold Roll Steel Slip Agent Coating by RAMA One of the major problems while the metallic pipe line has installed in the salty area is about the corrosion. In fact the common problem of the metallic pipe line typically can not be durable with the oxidization phenomenon. With the above mentioned reason our research and developement department has intened the better product that will enhance the corrosive tolerance capability and more convenience when installation called Tri-Coat technology, in abbreviation 3C technology, which include EMT, IMC, RSC. RSC Testing Result 24 hours 48 hours 72 hours 96 hours DAIWA 3c DAIWA KMUTT Laboratory The resulf from Salt Spray tester following ASTM B117 is show that Conventional RSC will occure 5% white rust at 24 hours whereas 3C RSC blitering at 72 hours and ocurre white rust at 96 hours. In conclution 3C product is persist Salt Spray more than the conventional product 4 times. Benefit of 3C coated Corrosive tolerance - More Durable - Lower Maintenace Cost - Smooth Surface
16 !"#$%&'(("%)%"%*&% THE ROOM RATCHADA LADPLO THE KEE RESORT & SPA +,!-.-/(!-"0(1-0'/2-*#* '3%("##4("-$& !3-# &%*'"-.()%+'/6-.(!-''-1-(7%-&3 +01(2-.0(&#*5#4/*/,4 '3%(0%%("%+#"'(8(+!- '3%(+%%5(&#*5#4/*/,4(+-'3#"*( '-0+/* +/-4((0%4!%*+0/ +/6-'%.9+/6-1-'3#* +,!-.-/(!"%4/%" '3%(-55"%++ &%*'"-.2#".5 &%*'"-.("-4-(: SUPALAI PARK YAK TIWANON CENTRAL FESTIVAL PATTAYA BEACH
17 Q HOUSE CONDO SATHORN!"#$%&'(("%)%"%*&% ;((3#,+%((&#*5#(+-'3#"* ;(("-*<(+,-* /*'"#(!-3#.1#'3/*((&#*5#4/*/,4 INTRO PAHOLYOTHIN CONDOMINIUM $-+4/*%("-4-(= >?((3%"/'-<%(&#*5#4/*/,4('#2%"(7 '3%((-.#)'(((3#'%. &%*'"/&(("-'&3-6/!- THE ROOM RATCHADA LADPLO
18 @C CENTRIC SCENE RATCHAVIPA./)%(B(+,03,46/'(D? &%*'%"!#/*'(7-*<("-0( '3%(-55"%++(+/-4(A( <%4#!#./+(4-..((:.%(4#*-&# &-!/'-.( Ratchada SIAM KEMPINSKI HOTEL (6 STARS)
NORMATIVE REFERENCES
American National Standards Institute NORMATIVE REFERENCES ANSI C135.30 1988 (expired 1993) Zinc-Coated Ferrous Ground Rod Electrodes for Overhead or Underground Lines American Society for Testing and
More informationNORMATIVE REFERENCES
American National Standards Institute NORMATIVE REFERENCES ANSI C135.30 1988 (expired 1993) Zinc-Coated Ferrous Ground Rod Electrodes for Overhead or Underground Lines American Society for Testing and
More informationSteel Nipples. Nipples & Fittings. Black and Galvanized Steel Nipples. Black and Galvanized. Steel Nipples. 142
PRODUCT SPECIFICATIONS Welded steel pipe nipples both galvanized an dblack in diameters ranging from 1/8 up to 4 in lengths from close to 12 and cut-pipe up to 120. TECHNICAL SPECIFICATIONS Standards:
More informationSECTION METAL FABRICATIONS
SECTION 05100 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for metal fabrications, including minimum requirements for fabricator, and galvanizing. 1.02 REFERENCE STANDARDS A. ASTM
More informationBarofor Round System (polyester coated) Panels, Posts, Accessories
1 Scope This Technical Data Sheet specifies the requirements for the Barofor Round System. The complete system exists of: Panels Posts Accessories such as fixation system and posts caps. Panels and posts
More informationInternational Organization for Standardization. American National Standards Institute
DFTG1329 Standards are published documents that set up rules, specifications and protocols designed to ensure consistency, compatibility and reliability of products, materials and services. Standards are
More informationOverview Better by Design
4 Ocal Corrosion-Resistant Conduit Systems Overview Better by Design Ocal Blue PVC-coated conduit and fittings represent a complete corrosion-protection package for your entire conduit system. This extensive
More informationPIPE/CONDUIT SUPPORTS
PIPE/CONDUIT SUPPORTS Pipe/Conduit Clamps...102-105 Unicushion... 106 Pipe & Tubing (Cush-A-Clamp ) Clamps...107-110 Pipe Hangers... 111 Pipe Rollers...111-112 Pipe Brackets... 113 Reference Tables...114-120
More informationGround Clamps Cable Tray
commercial and industrial fittings: ing Fittings and Solderless Connectors Clamps Cable Tray Terminates ground wire to cable tray. For aluminum or copper conductors. 1 4 hex wrench tightens both tray and
More informationPART MATERIALS. Section Fencing Materials. Description
PART 03000 - MATERIALS Section 03010 - Fencing Materials Description 03010.00 Scope - This section consists of the test requirements, specifications and tolerances for barbed wire, woven wire and chain
More informationStandard Specification for Electric-Resistance-Welded Metallic-Coated Carbon Steel Mechanical Tubing 1
Designation: A 787 05 Standard Specification for Electric-Resistance-Welded Metallic-Coated Carbon Steel Mechanical Tubing This standard is issued under the fixed designation A 787; the number immediately
More informationBP12W2 SPRG 3/4" Cond to Rod FSTNR. Features. Long Description
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 BP12W2 SPRG 3/4" Cond to Rod FSTNR Cooper B-Line/Cable Tray Catalog Number Manufacturer Description Weight per unit Product
More informationOverview Better by Design
4Conduit & Fittings Ocal Corrosion-Resistant Conduit Systems Overview Better by Design Ocal PVC-coated conduit and fittings represent a complete corrosionprotection package for your entire conduit system.
More informationINTERMEDIATE METAL CONDUIT
PRODUCT GUIDE 08 CONDUIT PIPES CONDUIT FITTINGS FITTINGS FOR FLEXIBLE CONDUITS METALLIC ELECTRICAL BOXES AND COVERS CONDUIT BODIES WEATHERPROOF BOXES AND COVERS CHANNELS & SUPPORTS METAL ENCLOSURES CHANNELS
More informationManufacturing Workmanship Standards. KSO Rev 1
Manufacturing Workmanship Standards KSO Rev 1 This document is a statement to the quality and workmanship by Kso Metalfab, Inc. The definitions, procedures, and responsibilities contained in this Workmanship
More informationA Full Line of Pipe Products for Any Application
Standard Pipe SureThread and ERW: Setting the standard in the standard pipe industry With a tradition of service and quality that s 80-plus years strong, Wheatland Tube is the only domestic, full-line
More informationMETRIC FASTENERS 1520 METRIC FASTENERS
1520 METRIC FASTENERS METRIC FASTENERS A number of American National Standards covering metric bolts, screws, nuts, and washers have been established in cooperation with the Department of Defense in such
More informationPIPING NOMENCLATURE. Header Branch connection Valve Flange Expansion joint Expansion loop Pipe support Reducer Elbow
PIPING COMPONENTS Piping components are mechanical elements suitable for joining or assembly into pressure-tight fluid containing piping systems. Components include pipe, tubing, fittings, flanges, gaskets,
More informationTesting. Material testing will be according to applicable AASHTO, ASTM or Department methods as specified.
907.01 Section 907. FENCING MATERIALS 907.01 General Requirements. Materials for use in fencing property, right-of-way and other installations must comply with this section. 907.02 Testing. Material testing
More informationBetter by Design. PVC Coated Conduit System. Technical Services Tel: Canada Tel: Fax:
PVC Coated Conduit System Overview Ocal Blue PVC coated conduit and fittings represent a complete corrosion protection package for your entire conduit system. This extensive product line includes the largest
More informationGURANTEED TECHNICAL PARTICULARS OF BACK CLAMP FOR LT CROSS ARM
Technical Specification of Back Clamp for LT Cross Arm (MS) Back clamp for LT Cross Arm made out of 50 x 6mm MS Flat suitable for 8m X 300 Kg PSC poles. After fabrication the cross arm shall be painted
More informationCABLE TRAYS & STRUTS CATALOUGE
CABLE TRAYS & STRUTS CATALOUGE We are the Manufacturer for Copper Bonded Ground Rod and Contract Manufacturing Company for other products made from Brass, Copper, Gunmetal, Bronze, Cast Iron, Malleable
More informationManufacturing Workmanship Standards YHF-WS Rev 2
Manufacturing YHF-WS Rev 2 Approved by & date: 02/25/16 Approved by & date: 02/25/16 This document is a statement to the quality and workmanship of York Haven Fabricators, Inc., henceforth referred to
More informationSECTION HOLLOW METAL DOORS AND FRAMES
PART 1 GENERAL 1.01 SECTION INCLUDES SECTION 08 11 13 HOLLOW METAL DOORS AND A. Non-fire-rated hollow metal doors and frames. B. Hollow metal frames for wood doors. C. Fire-rated hollow metal doors and
More informationQUALITY ASSURANCE SPECIFICATION
Page 1 of 8 QAS: 2.02 QUALITY ASSURANCE SPECIFICATION REVISION: 0 DATE: 08/29/14 MATERIAL PURCHASING Code Material Purchase Specification for Pipe, Valves, Fitting, and Flanges PAGE 1 OF 8 1.0 Purpose
More informationC0ND112G 1-1/2" Gray PVC CTD Cond STL RGD
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 C0ND112G 1-1/2" Gray PVC CTD Cond STL RGD Thomas & Betts Catalog Number Manufacturer Description Weight per unit Product
More informationCOMMERCIAL ITEM DESCRIPTION RODS, GROUND (WITH ATTACHMENTS)
INCH-POUND 30 May 2002 SUPERSEDING A-A-55804 11 March 1996 COMMERCIAL ITEM DESCRIPTION RODS, GROUND (WITH ATTACHMENTS) The General Services Administration has authorized the use of this commercial item
More informationRR-F-191/1D 14 May SUPERCEDING RR-F-191/1C July 22, 1981 FEDERAL SPECIFICATION SHEET
14 May 1990 ----------- SUPERCEDING RR-F-191/1C July 22, 1981 FEDERAL SPECIFICATION SHEET FENCING, WIRE AND POST METAL (CHAIN-LINK FENCE FABRIC) (DETAIL SPECIFICATION) This Federal Specification is approved
More informationSecurifor Polyester Coated Welded Mesh Panels
1 Scope This specification specifies requirements for panels made out of galvanised steel wires, welded and subsequently polyester coated for fencing. The panels are used for fencing, schools, public buildings,
More informationANSI ORIFICE FLANGES METAL-KOREA
METAL-KOREA ANSI ORIFICE FLANGES ORIFICE FLANGES are widely used in conjunction with orifice meters for measuring the rate of flow of liquids and gases. They are basically the same as standard welding
More informationUNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCEC / NASA UFGS-27 05 28.36 40 (May 2017) --------------------------------- Preparing Activity: NASA Superseding UFGS-27 05 28.36 40 (August 2014) UNIFIED FACILITIES GUIDE SPECIFICATIONS
More informationManufacturing Workmanship Standards Implemented November 2011
Manufacturing Implemented November 2011 ~ 1 ~ This document is a statement to the quality and workmanship by York Haven Fabricators, Inc., henceforth referred to as YHF. The definitions, procedures, and
More informationThru Wall Floor Seals For New Installation
The O-Z/Gedney Thruwall and Floor Seals provide a positive means of sealing pipe, conduit or tube where they pass through a concrete foundation of a structure below grade or below ground water level or
More informationCOMPATIBILITY OF FASTENERS
COMPATIBILITY OF FASTENERS TECHNICAL BULLETIN Vol. 4, No. 2 NOVEMBER 2011 This bulletin applies to conditions where fasteners are not provided by Metl-Span. Profiled metal roof or wall panels rely upon
More information5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.
2 1/2" x 2 1/2" x 10 Ga. 6" 5" 4" Variable Slipbase (8" Sq. SYS.) 5/16 Corner Bolt W/ nut 5/16" Flange nut Stub Insert (8" Sq. SYS.) Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc
More informationCONTINUING EDUC ATION
3 CONTINUING EDUC ATION FOR WISCONSIN ELECTRICIANS 2017 NEC Article 250 2 Hours WISCONSIN CONTRACTORS INSTITUTE N16 W23217 Stone Ridge Drive Suite 290 Waukesha, WI 53188 262-409-4282 www.wcitraining.com
More informationUFGS (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS
USACE / NAVFAC / AFCESA / NASA UFGS-27 05 28.36 40 (August 2011) ----------------------------------- Preparing Activity: NASA Superseding UFGS-27 05 28.36 40 (November 2008) UNIFIED FACILITIES GUIDE SPECIFICATIONS
More informationSECTION CABLE TRAYS
SECTION 16139 CABLE TRAYS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,
More informationSprinkler wet pipe and dry pipe. For FM approval of the dry pipe model "I" shall be used. SBF 120: 7 applies to model "E".
Product Name Nordic Flow FM Thin Wall Pipes Application Sprinkler wet pipe and dry pipe. For FM approval of the dry pipe model "I" shall be used. SBF 120: 7 applies to model "E". Manufacturing Standard
More informationA Full Line of Pipe Products for Any Application
Standard Pipe Standard Pipe: SureThread and ERW Setting the standard in the standard pipe industry With a tradition of service and quality that s 80-plus years strong, Wheatland Tube is the only domestic,
More informationGeneral Information...SA1-SA4
SECTION S INDEX Product Description Page Number General Information................................................................SA1-SA4 Type FSK Thruwall & Floor Seal For Conduit, Pipe or Tubing............................
More information2 MIL BLUE URETHANE COATED INTERIOR, 40 MIL PVC COATED EXTERIOR
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 CPL3 3" Gray PVC CTD Coupling Thomas & Betts Catalog Number Manufacturer Description Weight per unit Product Category
More informationInternational Tube & Conduit Company Ltd. BRITISH STANDARD STEEL CONDUITS & FITTINGS
International Tube & Conduit Company Ltd. BRITISH STANDARD STEEL CONDUITS & FITTINGS 1 ABOUT THE COMPANY VISION STATEMENT We strive to exceed our customers expectations through leading edge technologies
More informationSUBMITTAL SHEET. Project Submittals by
Galvanized Tie Wire and Hanger Wire Submittal of Product Performance SUBMITTAL SHEET Project Submittals by GRABBER CONSTRUCTION PRODUCTS, INC. Submittal Date: Contract Number: Project Name: Section Number:
More informationo r r o s i o n s o l u t i o n s 805.409.4050 www.okote.net I I the o kote AdVAntAGE A tradition of High standards in orrosion Protection orrosive elements cause millions of dollars in damage through
More informationASTM A684/AISI 1055 HEAT TREATED COLD ROLLED HCS
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com Catalog Number Manufacturer Description BP12U58 SPRG 3/4 CND-BM FSTNR Cooper B-Line/Cable
More informationDescription Cast Device Box, Height Inch; Width 2.81 Inch; Depth 2.69 Inch; Capacity 25 Cu Inch; 1 Gang; 2 Hub(S); Hub Location End;
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 1100 1G Mall Box Appleton/Oz Gedney Catalog Number 1100 Manufacturer Appleton/Oz Gedney Description Cast Device Box, Height
More informationWORKSHOP DRAWING & DESIGN STANDARDS
WORKSHOP DRAWING & DESIGN STANDARDS Purpose: Function: Content: This handout is intended to provide a summary of basic drawing guidelines which will: a) enhance communication between you and the workshop
More informationMEASURING ROLLER RUNOUT WHEN BUILT FROM WELDED TUBING
MEASURING ROLLER RUNOUT WHEN BUILT FROM WELDED TUBING There are various methods and descriptions used in measuring roller run-out. Many of these slang methods are incorrect. The measurement and drafting
More informationGOST TUBING AND COUPLINGS
GOST 633-80 TUBING AND COUPLINGS Tubing is used for oil and gas production. Tubing shall be made seamless, plain- or upset end and couplings with high-seal connections. Coupling-free connections are possible.
More informationSECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section
02760-1 of 5 SECTION 02760 STEEL LIGHTING STANDARDS 02760.01 GENERAL A. Description Steel lighting standards shall include, but not necessarily be limited to, furnishing and installing steel lighting poles,
More informationIndian Standard SPECIFICATION FOR USE IN FOUNDRIES. 1.1 This standard covers the requirements for chaplets for use in foundries.
Indian Standard SPECIFICATION FOR USE IN FOUNDRIES 1. SCOPE 1.1 This standard covers the requirements for chaplets for use in foundries. 2. SUPPLY OF MATERIAL 2.1 General requirements relating to the supply
More informationBol FEATURES: SPECIFICATIONS: 8' 24' Round Tapered and Straight Wood Poles STRUCTURA INC. FIXTURE TYPE: PROJECT NAME:
Bol 8' 24' Round Tapered and Straight Wood Poles FIXTURE TYPE: PROJECT NAME: Round Taper Glulam solid wood and aluminum pole available in 8' 24' lengths. Tenon adapters, slip fitters and side bracket mounts
More informationTAPTITE Fasteners. High Performance Thread Rolling Screws for Metals
TAPTITE 2000 Fasteners High Performance Thread Rolling Screws for Metals TAPTITE 2000 thread forming technology joins two unique concepts and advances fastener performance to new levels. TAPTITE 2000 fasteners
More informationCoatings ASTM B117 SST Salt Spray Test Kesternick Phosphate Zinc E-Coat Dip Spin Coatings
Head and Thread types Coatings ASTM B117 Two major types of coating tests: SST Salt Spray Test screws are placed in a container and a salt solution is sprayed on the screws for a number of hours, checking
More informationVersai Evolution of Versatile Fencing
Versai Evolution of Versatile Fencing About Versai Ornamental Fencing Versai Ornamental Fencing Versai Ornamental Fencing by Fortress is the next generation in ornamental fencing. It offers a solution
More informationASSIGNMENT 2. Textbook Assignment: 2-1. Levels are designed for which of the following purposes?
ASSIGNMENT 2 Textbook Assignment: "Levels," "Plumb Bulbs," "Scribers," "Squares," "Surface, Depth, and Height Gages," "Ring and Snap Gages and Gage Blocks," "Miscellaneous Measuring Gages," "Pliers and
More informationSECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS
SECTION 270536 - CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationDOCUMENT ADDENDUM NO. 4. Issued to all Bidders: Date: October 14, Contract Name: Electrical Installation. Contract Number: C8410
DOCUMENT 009104 - ADDENDUM NO. 4 Issued to all Bidders: Date: October 14, 2015 Contract Name: Electrical Installation Contract Number: C8410 This addendum forms a part of the Bid described above. The original
More informationSECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM).
PART 1 - GENERAL 1.1 SECTION INCLUDES A. Benches. B. Trash receptacles. C. Bike storage. 1.2 REFERENCE STANDARDS A. Including but not limited to: 1. American Society for Testing and Materials (ASTM). 1.3
More informationEngineering Test Report
Engineering Test Report Thermal Diffusion Galvanizing Report Poleline Hardware 02/01/2018 Allied Bolt s Thermal Diffusion Galvanizing Allied Bolt announces the launch of Thermal Diffusion Galvanized Poleline
More informationSymphony II Adaptable Table System
Symphony II Adaptable Table System 1.00 General 1.01 Conditions 1.02 Scope of work 1. This section covers all materials, equipment, tools and labor for the supply and installation of the laboratory Symphony
More informationConduit End Bells...EA1 Hex Reducing Bushings...EA2 Conduit Hubs...EA3-EA4. Split Couplings...EA5 Three Piece Couplings...EA6 Conduit Nipples...
SECTION E INDEX Product Description Page Number Conduit End Bells.......................................EA Hex Reducing Bushings..................................EA2 Conduit Hubs......................................EA-EA4
More informationNAVSEA STANDARD ITEM
NAVSEA STANDARD ITEM FY-19 DATE: 01 OCT 2017 CATEGORY: I 1. SCOPE: 1.1 Title: Threaded Fastener Requirements; accomplish 2. REFERENCES: 2.1 Standard Items 2.2 S9086-CJ-STM-010/075, Fasteners 3. REQUIREMENTS:
More informationMECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions
conduit? 9/8/10 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. Can branch circuits of different services be installed in the same Yes, see 300.3(C)(1) for conductors of different systems
More informationSECTION BULLET- RESISTANT DOORS
1 SECTION 08 3950 BULLET- RESISTANT DOORS PART 1- GENERAL 1.01 SUMMARY A. This Section Includes: 1. Bullet- resistant steel door and frame systems. 2. Door hardware for bullet- resistant steel door and
More informationMH Series Mitered Frames shall be as manufactured or furnished by Republic Doors and Frames, McKenzie, Tennessee
drywall frames - mh series/mitered SHEET NO. 202 MH Series Mitered Frames shall be as manufactured or furnished by Republic Doors and Frames, McKenzie, Tennessee 38201. Profile - Made for two basic door
More informationSECTION WIREWAYS FOR RADIOLOGY EQUIPMENT
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 05 36 WIREWAYS FOR RADIOLOGY EQUIPMENT SPEC WRITER NOTE: Delete between //----// if not applicable to project. Also, delete any other item or paragraph not applicable
More informationD. Thermally Sprayed Metallic Coating (Flame Spray): STD SPEC
STANDARD SPECIFICATION SECTION 05121 MISCELLANEOUS METALWORK PART 1 - GENERAL 1.01 DESCRIPTION This section includes materials, fabrication, and installation of structural steel, connecting bolts, pipes,
More informationSECTION CABLE TRAYS FOR ELECTRONIC SAFETY AND SECURITY
SECTION 26 05 36 CABLE TRAYS FOR ELECTRONIC SAFETY AND SECURITY PART 1 -GENERAL 1.1 SUMMARY A. Section includes cable tray. 1.2 REFERENCES A. ASTM A 123 Standard Specification for Zinc (Hot-Dip Galvanized)
More informationStructural Bolting. Notice the Grade 5 has a much smaller head configuration and a shorter shank then the grade A325 structural bolt.
Structural Bolting ASTM F3125/F3125M is a structural bolt specification covering inch and metric bolt grades. This specification contains 4 inch series bolting grades: A325, F1852, A490, and F2280. These
More informationSpecifications - Common Nails Diamond point, Flat head, round smooth shank, Bright, HDG, EG or cement coated (resin or vinyl) finish
Specifications - Common Nails Diamond point, Flat head, round smooth shank, Bright, HDG, EG or cement coated (resin or vinyl) finish ASTM F 1667-05 Table 15 Type 1, Style 10 - Common Nails Size Length
More informationTap Drill Chart. Metric Tap Drill Size (Recommended Drill Sizes Suitable for 6H Tolerance) Roll Form Tap Drill Size
Tap Drill Chart Tap Size Nom. Size Tap Cutting Tap Drill Size Metric Tap Drill Size (Recommended Drill Sizes Suitable for 6H Tolerance) Roll Form Tap Drill Size Machine Screw Sizes NC & NF Tap Size Cutting
More informationCONDENSATE DRAIN PANS
CONDENSATE DRAIN PANS TOTALINE CONDENSATE DRAIN PANS Totaline Condensate Drain Pans prevent harmful overflow moisture from reaching ceiling tiles, insulation or living space. Especially used in the attic
More informationKhathij Industrial Fasteners
Dear Sir/Madam, Khathij Industrial Fasteners This is Saqubar Sadique representing 'KHATHIJ INDUSTRIAL FASTENERS' from Chennai, India. We 'Khathij industrial fasteners' like to introduce us as a Stockist
More informationWAL-MART SUPERCENTER # ; Milwaukie, OR: SPECIFICATIONS. Revisions to Specification Fence
MILWAUKIE OR #3144-00 ADDENDUM #5 NARRATIVE: 11-08-12 WAL-MART SUPERCENTER #3144-00; Milwaukie, OR: SPECIFICATIONS SPECIFICATIONS Revisions to Specification 02822 Fence Spec division 02822 has been revised
More informationGLOSSARY OF TERMS SECTION 8
GLOSSARY OF TERMS SECTION 8 Anchor Bolt Angle Base Plate Bay Blocking CCB Centerline Chord Cladding Clip Closure Strip An A-307 steel bolt embedded in the concrete footing to anchor the base plate of the
More informationBCI General Specifications Design: BCI Gothia Shelving System
BCI General Specifications Design: BCI Gothia Shelving System SH7.0 General Product Design and Construction SH7.0.1 The shelving system is constructed with vertical frames connected by horizontal and diagonal
More informationWisconsin Contractors Institute Continuing Education
IMPORTANT NOTE: You should have received an email from us with a link and password to take your final exam online. Please check your email for this link. Be sure to check your spam folder as well. If you
More informationSCREW FASTENER SELECTION FOR COLD-FORMED STEEL FRAME CONSTRUCTION
test TECHNICAL NOTE On Cold-Formed Steel Construction $5.00 Cold-Formed Steel Engineers Institute Washington, DC www.cfsei.org 866-465-4732 SCREW FASTENER SELECTION FOR COLD-FORMED STEEL FRAME CONSTRUCTION
More informationWoven Steel Wire Fence Type-47. Under the state specification for fencing, ASTM A 116 is called out.
Woven Steel Wire Fence Type-47 Under the state specification 710.02 for fencing, ASTM A 116 is called out. Go to the steel and fencing certification manual for more information about the basic properties
More information1. ANSI/ASME Standard B , Square and Hex Bolts and Screws, Inch Series
SECTION 31 66 13 HELICAL PILES AND HELICAL ANCHORS PART 1 - GENERAL 1.1 DESCRIPTION A. This work pertains to furnishing and installing Helical Piles and Bracket Assemblies shown in the Contract in accordance
More informationAnnie Tel: MSN: All chain-link fences aren't the same
Attractive, versatile and creative - a chain-link fence system can be an excellent choice. With the right fence you can expect years of protection, privacy and value. But as with any investment, it pays
More informationA. Product Data: For each electrical identification product indicated.
SECTION 16075 - ELECTRICAL IDENTIFICATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationISO INTERNATIONAL STANDARD. Hexagon bolts with flange with metric fine pitch thread Small series Product grade A
INTERNATIONAL STANDARD ISO 15072 First edition 1999-12-15 Hexagon bolts with flange with metric fine pitch thread Small series Product grade A Vis à tête hexagonale à embase cylindro-tronconique, à filetage
More informationSECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP
1 1 1 0 1 0 1 0 1 SECTION 1 1 CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP BASED ON DFD MASTER SPECIFICATION DATED /01/ P A R T 1 - G E N E R A L SCOPE The work under this section shall consist of
More informationHilti, Inc South 122 nd East Avenue Tulsa, OK
Attached are page(s) from the 2013 Hilti North American Product Technical Guide Volume 1 Direct Fastening. For complete details on this product, including data development, product specifications, general
More informationSteel Couplings. Product Specifications Welded steel couplings both galvanized and black in diameters from 1/8 up to 4
Merchant Couplings Steel Couplings Merchant Couplings Product Specifications Welded steel couplings both galvanized and black in diameters from 1/8 up to 4 Technical Specifications Standards: Product complies
More informationSTEEL PIPE GUIDERAIL 01/01/
NOTES PIPE RAILING & POSTS: Pipe Rails and s shall be in accordance with ASTM A5 Grade B for standard weight pipe and ASTM A500 Grade B, C or D or ASTM A50 for structural tube. Bars for handrail supports
More informationStandard Specification for Fence Fittings 1
Designation: F 626 08 Standard Specification for Fence Fittings 1 This standard is issued under the fixed designation F 626; the number immediately following the designation indicates the year of original
More informationALUMINUM PIPE GUIDERAIL 01/01/
NOTES PIPE RAILING & POSTS: Structural Tube, Pipe and Bar shall be in accordance with ASTM B22 or ASTM B429, Alloy 606-T6. End Rail 90 bends and corner bends with maximum 4-0" post spacing, may be Alloy
More informationSTAR TOOL SUPPLY / GRAND TOOL SUPPLY
MULTIPURPOSE CLAMPS - USA SERIES 7: Lightweight and 4% stronger than C clamps. Floating jaws that always stay parallel. Designed to eliminate distorting or twisting action. Cantilever action provides 4:
More informationSection COUPLINGS AND COUPLING ADAPTERS. This Section covers couplings and coupling adapters for ductile iron and steel pipe.
PART 1 GENERAL 1.01 SUMMARY Section 15155 This Section covers couplings and coupling adapters for ductile iron and steel pipe. 1.02 MEASUREMENT AND PAYMENT A. No separate payment for Work performed under
More informationMAG-MATE* Series 300 Terminals
MAG-MATE* Series 300 Terminals Application Specification 114-2046 28 NOV 18 Rev AB All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches].
More informationTENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018
SECTION 055000 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply
More informationNON-PENETRATING ROOFTOP HANGERS AND SUPPORTS
SECTION 15062 NON-PENETRATING ROOFTOP HANGERS AND SUPPORTS For best results, display hidden notes to specifier. PART 1 GENERAL 1.1 SECTION INCLUDES A. Pipe supports. B. Conduit supports. C. Duct supports,
More informationINFUSIONS and METALWORKS Wings Accent and Acoustical Clouds
INFUSIONS and METALWORKS Wings Accent and Acoustical Clouds Assembly and Installation Instructions 1. GENERAL 1.1 Product Description Wings is a decorative ceiling element consisting of a 10 foot long
More informationBOLTS AND NUTS Square Bolts( Table 1 ) Hex Nuts ( Table 7 ) Heavy Hex Nuts (Table 7) Heavy Hex Structural Bolts ( Table 2 )
BOLTS AND NUTS 1493 An externally threaded fastener that must be assembled with a nut to perform its intended service is a bolt. (Example: heavy hex structural bolt.) An externally threaded fastener that
More informationCOMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationFEDERAL SPECIFICATION SHEET FENCING, WIRE AND POST, METAL (CHAIN-LINK FENCE ACCESSORIES) (DETAIL SPECIFICATION)
14 May 1990 SUPERSEDING RR- F-191/4C July 22, 1981 FEDERAL SPECIFICATION SHEET FENCING, WIRE AND POST, METAL (CHAIN-LINK FENCE ACCESSORIES) (DETAIL SPECIFICATION) IIIisFederal specification is approved
More information